What are the emission limitations for air curtain incinerators?
40 C.F.R. § 60.2860
in effectAfter the date the initial stack test is required or completed (whichever is earlier), you must meet the limitations in paragraphs (a) and (b) of this section:
(a) Maintain opacity to less than or equal to 10 percent opacity (as determined by the average of three 1-hour blocks consisting of ten 6-minute average opacity values), except as described in paragraph (b) of this section; and
(b) Maintain opacity to less than or equal to 35 percent opacity (as determined by the average of three 1-hour blocks consisting of ten 6-minute average opacity values) during the startup period that is within the first 30 minutes of operation.
Source: ecfr_bulkFetched: 7/26/2026
Source: eCFR APIURL: https://www.ecfr.gov/api/versioner/v1/full/2024-07-01/title-40.xml?part=60Fetched: 5/31/2026